Water Treatment Chemical professional and technical network

Water Treatment Chemicals

   WATER TREATMENT CHEMICALS
Organophosphoric Antiscale and Corrosion Inhibitors, Chelants
Organophosphoric Salts
Polycarboxylic antiscale and dispersant
Biodegradable antiscalant and dispersant
Bactericide and Algicide
Built Scale & Corrosion Inhibitors and Pretreatment Filming Agents
  TH-907 Non-P Scale & Corrosion Inhibitor
  TH-503 Scale and Corrosion Inhibitor for Boiler
  TH-503B Scale and Corrosion Inhibitor for Boiler
  TH-504 Scale and Corrosion Inhibitor for Heating Water
  TH-601 Scale and Corrosion Inhibitor for Iron & Steel Plant
  TH-604 Scale and Corrosion Inhibitor for Power Plant
  TH-607 Scale Inhibitor for Oilfield Refill Water
  TH-607B Scale Inhibitor for Barium and Strontium
  TH-610 Scale Inhibitor for Dusty Water
  TH-619B Scale and Corrosion Inhibitor
  TH-628 scale and Corrosion Inhibitor
  TH-658 Scale And Corrosion Inhibitor For High Hardness Water
  TH-682 Scale and Corrosion Inhibitor for low hardness water
  Corrosion Inhibitor For Closed Circulating System
  TH-701 Nonstop Cleaning agent
  TH-706 Deoiling Detergent
  TH-707 Pretreatment Filming Agent
Corrosion Inhibitor
Oxygen Scavenger
Reverse Osmosis Chemicals
Others
 Home > Water Treatment Chemicals > Built Scale & Corrosion Inhibitors and Pretreatment Filming Agents

TH-503 Scale and Corrosion Inhibitor for Boiler

Properties and usage:

TH-503 is built with organophosphine and polycarboxylic acid. It has advantages of high efficiency of scale & corrosion inhibition and good temperature tolerance. TH-503 can be used in water treatment of low pressure boiler. Boilers include radiator, steam, locomotive, etc. This product can also be used as scale and corrosion inhibitor in situation of desalination plant, distillation and bus water tank.

Usage:

Add 200g per ton water of this product into boiler make-up water. During operation, blow-off every hour, 5-10 second each time. If the boiler has heavy scale, increase the quantity, and frequently blow-off. After 10-20 days' continuous operation, stop the boiler, open the handhole, remove the visible scale deposit to prevent conduit blockage, then, the boiler may turn into normal operation again. TH-503 would be better if the condense index of boiler water was controlled within 10. Other parameters may refer to related regulations (boiler water pH10-12, for example). pH value should not be lower than 7.

The material of medicate tank should be in plastic, concrete tank should be pretreated by anticorrosion method, otherwise, it will be eroded by the medicine, and the hardness will be increased much high.

Total hardness of boiler make-up water should be lower than 200mg/L. Once too high hardness is countered, lime or other methods should be used to lower it . 

Package and Storage:

200L plastic drum,IBC(1000L),customers’ requirement. Storage in shady room and dry place for one year.

Safety Protection:

Though no toxic, this product is acidic and corrosive, once contacted with skin, flush with water.

 

Tel: +86-632-5113066  Fax: +86-632-5112055  E-mail:info@thwater.net
ADDR: No.1, Shiliquan East Road, Shizhong District, Zaozhuang City, Shandong Province, P.R.China
Copyright © 2007-2023 Shandong Taihe Technologies Co., Ltd. All rights reserved